詳細信息
********************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************
1.General Instruction
General Specifications | ||||||
Normal Type | MF-0204 | MF-0207 | MF-0410 | MF-0414 | MF-0617 | MF-0718 |
Rated Power | 1/8W | 1/4W | 1/2W | 1W | 2W | 3W |
Mini Type | MF-0207S | MF-0410S | MF-0414S | MF-0617S | MF-0718S | MF-0925S |
Rated Power | 1/4WS | 1/2WS | 1WS | 2WS | 3WS | 5WS |
Standard Dimensions (mm) | ||||||
Body Length (L) | 3.5±1.0 | 6.5±1.0 | 9.0±1.0 | 11±1.0 | 15±1 | 17±1 |
Body Diameter (D) | 1.7±1.0 | 2.3±1.0 | 3.2±1.0 | 4.5±1.0 | 5.0±0.5 | 6±0.5 |
Lead Length (H)±2 | 27±2.0 | 26±2.0 | 25±2.0 | 30±2.0 | 33±2.0 | 33±2.0 |
Lead Diameter (d) ± 0.05 | 0.40±0.05 | 0.48±0.05 | 0.52±0.05 | 0.72±0.05 | 0.72±0.05 | 0.72±0.05 |
Electrical Specification | ||||||
Din Size | 0204 | 0207 | 0410 | 0414 | 0617 | 0718 |
Maximum Working Voltage (V) | 200 | 250 | 350 | 500 | 500 | 500 |
Maximum Overload Voltage (V) | 400 | 500 | 700 | 1000 | 1000 | 1000 |
Resistance Range (±1%(F)) | 0.1Ω-1MΩ | 0.1Ω-1MΩ | 0.1Ω-1MΩ | 10Ω-100K | 10Ω-100K | 10Ω-100K |
(±0.5%(D)) | 100Ω-511KΩ | 100Ω-511KΩ | 100Ω-511KΩ | 100Ω-51KΩ | 100Ω-51KΩ | 100Ω-51KΩ |
FOperating Temperature. Range:-55℃~ +155℃.
FS=Miniature Type. For Example:0207S the body size of 1/8W but with rated power of 1/4W.
FThe taping dimension other than the standard is also available as per our taping specifications.
FThe resistance range of lower than 10Ωand higher than 1MΩand / or the tolerance is lower than 0.5% are available on special request.
FColor of Body: Normal type is Blue.
FPackaging: Taped / Box and Bulk.
FForming: P / M / MB / MK / F / FK1 / FK2 & FKK .
FStandard:JIS-C-5202
|
2. Performance Specifications
Characteristics | Standard | Test Methods | |||||
1. Resistance Temperature Coefficient (PPM/℃) | ±100 PPM/℃ | Natural resistance change per temperature degree centigrade. (PPM/℃) R1: Resistance value at reference temperature. (T1) R2: Resistance value at reference temperature.(T2) T1: Room Temperature T2: T1±100℃ | |||||
2. Dielectric Withstanding Voltage | No evidence of flashover, mechanical damage or arcing or, insulation break down. | Resistors shall be subjected to an approximately sinusoidal test potential (as below) 60Hz applied between both terminals connected together and a 90° V-Block extending beyond the end of the resistor. | |||||
Resistor Wattage | DC Volts | ||||||
1/8W (1/4WSi) 1/4W (1/2WS) 1/2W 1W,2W Above | 150 350 600 | ||||||
3. Solderability | 90% Covered min. | The terminal lead shall be dipped into molten solder s at 3.2 to 4.8mm from the body of resistor.The temp. and time as below: a. 235±5℃for 2±0.5 seconds b. 270±10℃for 2±0.5seconds | |||||
4. Resistance to Soldering | No evidence of mechanical damage ΔR/R at ±0.5% Max | The terminal of the resistor is dipped into the molten solder of 350±10℃for 3±0.5 seconds. Then put the resistor in the room temperature. For min.3 hours. | |||||
5. Humidity Load Life | ±1% Max/1000Hours | Resistance change after 1000 hours ( 1.5 hours on 0.5 hours off)at rated continuous working voltage in a humidity chamber controlled at 40±2℃and 90~95% relative humidity . | |||||
6. Load Life | ±1% Max/1000Hours | Permanent resistance change after 1000 hours operating at rated continuous working voltage with a duly cycle of 1.5 hours on 0.5 hours off at 70 ± 2℃ambient . | |||||
7. Temperature Cycling | ±1% Max with no evidence of mechanical damage | Resistance change after continuous five cycles for duty cycle as specified below. | |||||
Step | Temperature | Time | |||||
1 | -30℃ | 30 Minutes | |||||
2 | +25℃ | 10~15 Minutes | |||||
3 | +85℃ | 30 Minutes | |||||
4 | +25℃ | 10~15 Minutes | |||||
Characteristics | Standard | Test Methods | |||||
8. Short Time Overload | ΔR/R at±0.5% Max. with no evidence of arcing burning, or charring | Permanent resistance change after the application of a potential of 2.5 times rated continuous working voltage for 5 seconds at room temperature. | |||||
9. Terminal Strength | No evidence of mechanical damage or loosening terminals | Direct load resistance to 2.5kg direct load 30±5 seconds twist test, for axial leads unit only. Terminal lead shall be bent through at a right angle at a point of 6.35mm from the body edge of resistor and shall be rotated through at a right angle about the original axis of the bent terminal in alternating direction for a total 3 rotations. | |||||